Safety Systems
IEC61508 SIL-3 Certified Systems
High-Performance Safety Systems For Turbines and Compressors
Machinery Protection Standard API670 requires compressor safety systems be used on axial compressors and centrifugal compressors based on application criticality. Woodward is a leader in delivering safety systems for industrial turbomachinery that allow users to meet this standard.
Woodward’s SIL-3 certifiable safety systems reduce installation costs and allow users to meet today’s safety system requirements for small, medium, or large compressor applications.

12.3.1.2
. If the turbine Vendor provides the shutdown system with the turbine, the turbine Vendor shall have unit responsibility for the entire shutdown system. If the trip system is not supplied by the turbine Vendor, the Supplier has to supply the response time of the trip systems component and the turbine Vendor shall review and comment on the proposed system.
12.3.1.3.
The turbine system shall include on-line diagnostics, testing functions and be able to be repaired on-line
.
12.3.3. Electro-hydraulic solenoids valves
12.3.3.5
The trip solenoids valves shall be provided with facilities to allow testing of the solenoid valve function while the turbine is in operatio
n.
12.4 Other alarms and shutdowns
16.3.4.7. Field system overspeed shutdown systems response test
If specified, after complete field installation, the Vendor is responsible or responsible party is required to provide Purchaser with actual measured total shutdown response times for at least four overspeed trip events as proof that the total system response time.
...
...
Contact us about anything related to our company or services.
We're looking forward to speak to you.